Robotics CS8C Manual de usuario Pagina 172

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 248
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 171
© Stäubli 2009 – D28070504A CS8C172 / 248
8.5.3.2. CASE 2
Check that D1 circuit breaker is on position 1.
If D1 circuit breaker does not remain on position 1, change ARPS and / or D1 circuit
breaker.
Check input fuses (F1, F2, F3):
Fuses are 10 x 38 mm type, 500V for standard controllers.
Check voltages at the input of the controller (L1, L2, L3).
Check voltages after the transformer. At this point, voltages are 230 VAC ±10% for all
the input voltages.
Change D1 circuit breaker.
To change D1 or D2 circuit breakers, remove PSM.
Problem:
D1 circuit breaker light is off.
Solution:
DANGER:
Main switch S1 should be in off position AND main power to the controller has
to be disconnected.
Orange wires inside PSM indicate that dangerous voltage remains even if S1
is off.
?
Vista de pagina 171
1 2 ... 167 168 169 170 171 172 173 174 175 176 177 ... 247 248

Comentarios a estos manuales

Sin comentarios