Robotics CS8C Manual de usuario Pagina 214

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 248
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 213
© Stäubli 2009 – D28070504A CS8C214 / 248
8.8.4.8. CASE 8
A major failure has been detected on the CPU:
Reboot controller.
If this error code remains:
Change the CPU.
Note:
Changing a CPU board requires an intervention level 2 or 3 to set up parameters of
the new CPU (level 2 if CPU is preconfigured, level 3 if not).
8.8.4.9. CASE 9
An open electric limit switch condition has been detected.
Note 1:
The presence and number of electrical limit switches depends on arm type (see
figure 8.51).
Note 2:
With RSI(1) board, limit switch circuit is powered from 24V.
With RSI2 board, limit switch circuit is powered from 24Vfus.
Check first F2 fuse on front of RSI2 (refer to error code #7).
Check that arm is inside the defined range through MCP Front Panel information.
Problem:
(2) Watch Dog open: Computer failure
Solution:
Problem:
(3) Electric stop activated in the arm: J101, 5-12
Solution:
?
?
Vista de pagina 213
1 2 ... 209 210 211 212 213 214 215 216 217 218 219 ... 247 248

Comentarios a estos manuales

Sin comentarios