Robotics CS8C Manual de usuario Pagina 190

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 248
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 189
© Stäubli 2009 – D28070504A CS8C190 / 248
8.6.6.4. ADVANCED INFORMATION
This output is a 24 VDC signal.
When there is no fault (status in control panel = ON) SECTEUR_OK signal is set to 24 V.
When there is a fault (status in control panel = OFF) SECTEUR_OK signal is set to 0V.
Figure 8.28
RSIARPS
J104-3
J104-8
J1102-14 SECTEUR_OK-
J1102-6 SECTEUR_OK+ 24V
GND
BRK-ON
Pin 8
ALIM-OK
24V1
24V1
24V2
13V
0 VDC+
SECTEUR-OK
BRK-REL-EN
Pin 1
Vista de pagina 189
1 2 ... 185 186 187 188 189 190 191 192 193 194 195 ... 247 248

Comentarios a estos manuales

Sin comentarios