8.8.4.10. CASE 10
Before checking faults on drives, check first that STARC board is operating properly (see
chapter 8.9, page 232).
Check on MCP Control Panel which drive is faulty and change the drive.
Figure 8.52
If there is no fault on drives, check wiring between drives and RSI.
Figure 8.53
Problem:
(4) Amplifier fault: Contact DF open on J112, 3-4. The events
history can be used to find the number of the amplifier
concerned, and it provides further information on the fault. The
control panel can also be used to display the status of the
various variable speed drives.